The sensor catalog

A sensor catalog says what each instrument is, by its serial number: the model, the maker and their entries in the NERC vocabularies. One catalog can serve every mooring of a lab or a project, so an instrument used on several moorings is described once. It holds no calibrations; those stay with the calibration dips (Calibration dips).

Stage 1 uses it to write the instrument’s sensor record (the SENSOR_<type>_<serial> variable, following OG1, since OceanSITES does not describe sensors). Without a catalog, the record carries only what the instrument file itself states.

Today the catalog covers SBE 37 MicroCATs.

An example

models:
  SBE 37-SMP:
    long_name: Sea-Bird SBE 37-SMP MicroCAT
    sensor_type: CTD
    sensor_type_vocabulary: https://vocab.nerc.ac.uk/collection/L05/current/130/
    sensor_maker: Sea-Bird Scientific
    sensor_maker_vocabulary: https://vocab.nerc.ac.uk/collection/L35/current/MAN0013/
    with_pressure:
      sensor_model: Sea-Bird SBE 37 MicroCat SMP-CTP (submersible) CTD sensor
      sensor_model_vocabulary: https://vocab.nerc.ac.uk/collection/L22/current/TOOL1457/
    without_pressure:
      sensor_model: Sea-Bird SBE 37 MicroCat SMP-CT with optional pressure (submersible) CTD sensor series
      sensor_model_vocabulary: https://vocab.nerc.ac.uk/collection/L22/current/TOOL0018/

instruments:
  "37-12046":
    model: SBE 37-SMP
    pumped: true
    sources:
      - {report: 2015_64PE400_NIOZ_cruise_report.pdf, pdf_page: 40,
         text: "Instrument - MicroCat SBE 37-SMP SN 12046 88m --> 172 m"}
models

One entry per model: long_name, sensor_type and sensor_maker with their vocabularies (NERC L05 and L35). The SeaVoX device catalogue (L22) lists a model with and without a pressure sensor separately, so each model gives both, as with_pressure and without_pressure. A MicroCAT with an optode is a model of its own (SBE 37-SMP-ODO).

instruments

One entry per instrument, keyed by the maker’s label ("37-12046" is SBE 37 MicroCAT 12046): its model, whether it is pumped, and sources, the documents that say so (a report, its page, the words quoted).

What stage 1 does with it

For each MicroCAT, stage 1 looks the instrument up by the serial in its mooring YAML entry, then by the serial its file states. When found, the sensor record gets the model’s attributes and the with_pressure or without_pressure entry, depending on whether the instrument measured pressure (values present, and at least one flagged good or none quality-controlled). sensor_pumped records the pumping, and sensor_model_source the documents.

An instrument entry’s own sensor_model in the mooring YAML wins over the catalog. When the instrument file states a different model, the file’s value is kept as originator_sensor_model and a warning is logged.

Stage 1 does not rerun when only the catalog changes; rerun with oceanarray run --force.

Using a catalog

Name the catalog in the mooring YAML (sensor_catalog:, relative to the mooring YAML). Planned: the catalog’s location moves to the call and the command line, like the other input locations, so the mooring YAML holds no path.